  Datasheet File OCR Text:
  wide 80-275vac input medical safety iec60601-1 3rd edition; 2mopp choice of iec320-c14, c8 or c6 input receptacles single outputs from 12 to 48 vdc effciency level v class i or class ii model number output watts output voltage output amps effciency total regulation *ahp6301(a,b,c)-05 63 12vdc 5.25 84% 5% *ahp6301(a,b,c)-06 63 15vdc 4.20 85% 5% *ahp6301(a,b,c)-07 63 18vdc 3.50 85% 5% *ahp6301(a,b,c)-08 63 24vdc 2.62 85% 3% *ahp6301(a,b,c)-09 63 30vdc 2.10 86% 3% *ahp6301(a,b,c)-10 63 36vdc 1.75 86% 3% * ahp6301(a,b,c)-11 63 48vdc 1.31 86% 3% * note: the asterisk * denotes a choice of receiving this product with an iec-320-c14 3 pole input receptacle (a) or with an iec-320-c8 2 pole input receptacle (b) or with an iec-320-c6 3 pole input receptacle (c). see the mechanical fles at the end of this specifcation for clarity . simply add the letter a, b or c after ahp6301 in the model number (i.e. ahp6301a-05 for c14 or ahp6301b-05 for c8 or ahp6301c-05 for c6) when ordering to receive the desired version. medical hpu63bseries 63wexternalmedicalgradepowersupply thehpu63bseriesofac/dcswitchingmodepowersupplies provide63wattsofcontinuousoutputpower.allsuppliesare ul94v-1mincompliant.all modelsmeetfccpart-18classband cispr-11en55011classbemissionlimitsandaredesignedto complywithansi/aamies60601-1:2005(ul/cul3rd edition),en 60601-1:2006(tuv/t-mark3rdedition)andnewcerequirements. allunitsare100%burnedinandtested. features: applications: generalspecification: *wideoperatingvoltage,80to275vac,47to63hz *iec-320-c8inputinlet *singleoutput *overvoltageandoverloadprotection *medicalsafety3rd(iec60601-13rdedition) *inputtooutput:2mopp *energystar2.0,efficiencylevelv *classiisystem *3yearwarranty *homehealthcareequipment *patientmonitor *bloodpressuresystem *portablemedicaldevices *ecgmachine * :autorecovery * :freeairconvection * :ul94v-1 * :doubleinsulated,classii :ansi/aamies60601-1:2005(ul/cul3rdedition),en60601-1:2006 (tuv/t-mark3rdedition) shortcircuitprotection cooling flammabilityrating protectionclasses *safety electricalcharacteristics: environmental: symbol characteristic condition min. typ. max. unit vac class vac vac hz w a a a a % %/c c rh rh kv kv kv h m g c % ms ms s symbol characteristic condition min. typ. max. unit vins safetyapprovalinputvoltagerange safetyapproval&specificationinlabel vin inputoperatevoltagerange inputfrequency detailtoseefig.1 (deratelinearlyfrom100%loadat90vacto80%loadat80vac) fi sinewave po outputpowerrange seeratingchart iil lowlineinputcurrent fullload,vin=100vac iih highlineinputcurrent fullload,vin=240vac irl lowlineinputinrushcurrent fullload,25c,coolstart,vin=100vac irh highlineinputinrushcurrent fullload,25c,coolstart,vin=240vac efficiency fullload,vin=230vac,detailtoseeratingchart voi lineregulation fullload,vin=100~120vacor200~240vac olp overloadprotection recoversautomaticallyafterfaultconditionisremoved ttr timeoftransientresponse fullload,vin=110vac thu hold-uptime fullload,vin=100vac ts start-uptime fullload,vin=100~240vac tc temperaturecoefficient allcondition hv dielectricwithstandingvoltage(p-s) primarytosecondary,limitcurrent<10ma emi to ts ho hs vsg esda esdc mtbf elev vbr emcemission compliancetoen55011(cispr11),en61000-3-2,-3 100 80 47 63 63 1.62 0.72 37 74 seeratingchart 110 12 0.3 4000 -10 0 0 2 8 6 100k 5 -40 b 150 70 85 95% 95% 3000 4 2 0.04 1 240 275 operatingtemperature storagetemperature operatinghumidity storagehumidity surgevoltage electrostaticdischarge electrostaticdischarge meantimebetweenfailure operatingaltitude(elevation) vibration detailtoseefig.2 (deratelinearlyfrom100%loadat40cto50%loadat70c) 10~95%rh non-condensing seeratingchart allcondition airdischarge,iec61000-4-2 contactdischarge,iec61000-4-2 operatingtemperatureat25c,calculatedpermil-hdbk-217f allcondition 10~500hz,10min./1cycle,60min.eachalongx,y,zaxes rohs 2011/65/eu 2 cb en 60601-1 iec 60601-1 s e p approvals: % ovp 112 132 overvoltageprotection 63w medical power adapters for health care applications ahp6301 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
* these are stress ratings. exposure of the devices to any of these conditions may adversely affect long term reliability. proper operation under conditions other than the standard operating conditions is neither warranteed nor implied. all specifcations are typical at nominal input, full load, and 25c unless other - wise noted input specifications input voltage range 80-275 vac (100-240 nominal) frequency range 47-63 hz input current low line (100vac) 1.62a max. high line (240vac) 0.72a max. inrush current, typ (cold start) low line (100vac) 37a max. high line (240vac) 74a max. leakage current (240 vin) 0.1ma no load power consumption 0.5 watts output specifications voltage and current see selection charts output power range 0 to fl rating load regulation 5%, max. 60%l, changing 10% line regulation (fl) 1%, max. changing line 10% over load protection * 110-150%, auto-recovery over voltage protection * 112-132% short circuit protection auto recovery transient response 110vin, fl 4ms temperature coeffcient 0.04%/c, typ ripple/noise (note 1) 100mv pk-pk max. hold up time (note 2) 100~240vin, fl 12ms min. start up time 100~240vin, fl 0.3s typ., 2s max. general specifications input-out isolation 4000 vac, limit current <10ma input-gnd 2800 vdc isolation resistance 50m? effciency (fl, 230vin) see selection chart safety ansi/aami es 60601-1:2005 (ul/cul 3rd edition), en 60601-1:2006 (tuv/t-mark 3rd edition) protection class ahp6301a, 6301c: class i ahp6301b: double insulated class ii physical specifications size 5.17 x 2.18 x 1.46 (131 x 55.4 x 37mm) construction desktop style weight 13.4oz (380g) flammability rating ul94v-1 environmental specifications oper. temperature -10 to +40c (fl) * 50% load @ 70c (see derate curve last page) cooling free air convection storage temperature -40 to +85c, 10~95% rh * operating humidity 0% to 95%, non-cond * emc compliance to en55011 (cispr11), en61000-3-2, -3 class b mtbf (mil-hdbk-217f) 100,000 hrs surge voltage 2kv esd - air iec61000-4-2, 8kv esd - contact iec61000-4-2, 6kv operating altitude (elevation) 3000m vibration 5g, 10 ~ 500hz, 10min./1cycle, 60min. each along x, y, z axes drop test 120cm, 1 ea. on six sides notes 1. ripple & noise is measured by using 20mhz bandwidth limited oscilloscope and terminated each output with a 0.47uf capacitor at rated load and nominal line. 2. hold up time is measured from the end of the last charging pulse to the time which the main output drops down to low limit of main output at rated load and nominal line. 63w medical power adapters for health care applications ahp6301 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
mechanical dimensions - ahp6301a dimensions are in mm [inches]. dc output connections coaxial plug: +vout -vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center + ahp6301x-05~07 output cord length 48, 16awg ahp6301x-08~10 output cord length 72, 18awg modifying the output cable will effect regulation and effciency 63w medical power adapters for health care applications ahp6301 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
mechanical dimensions - ahp6301b dc output connections coaxial plug: +vout -vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center + ahp6301x-05~07 output cord length 48, 16awg ahp6301x-08~10 output cord length 72, 18awg modifying the output cable will effect regulation and effciency dimensions are in mm [inches]. 63w medical power adapters for health care applications ahp6301 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
mechanical dimensions - ahp6301c dc output connections coaxial plug: +vout -vout 5.5mm outer diameter 2.1mm inner diameter, female 11mm length, center + ahp6301x-05~07 output cord length 48, 16awg ahp6301x-08~10 output cord length 72, 18awg modifying the output cable will effect regulation and effciency dimensions are in mm [inches]. 63w medical power adapters for health care applications ahp6301 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458
medical hpu63bseries 63wexternalmedicalgradepowersupply specificationnote: 1.outputcanprovideuptopeakloadwhenthepowersupplystartsup. continuousstayinginmorethanratedloadisnotallowed. 2.atfactory,in60%ratedloadcondition,eachoutputischeckedtobe withinvoltageaccuracy. 3.lineregulationisdefinedbychanging10%ofinputvoltagefrom nominallineatratedload. 4.loadregulationisdefinedbychanging40%ofmeasuredoutputload from60%ratedload. 5.ripple&noiseismeasuredbyusing20mhzbandwidthlimited oscilloscopeandterminatedeachoutputwitha0.47ufcapacitorat ratedloadandnominalline. 6.holduptimeismeasuredfromtheendofthelastchargingpulsetothe timewhichthemainoutputdropsdowntolowlimitofmainoutputat ratedloadandnominalline. 7.efficiencyismeasuredatratedload,andnominalline. 8.thespecificsfortestingtheenergyefficiencyofthisseriesareoutlined inaseparatedocumenttitled"testmethodforcalculatingtheenergy efficiencyofsingle-voltageinterchangeableac-dcandac-acpower supplies(august11,2004),"whichisavailableontheenergystar website. mechanicaldimensions: (unit:mm) outputcablerecommend: packing: 1.selectedoutputconnectorsandwire,pleaserefertoappendix. 2.hpu63b-105~107arerequiredtouseawg#16/4ftoutputcable. 3.hpu63b-108~111arerequiredtouseawg#18/6ftoutputcable. 4.theregulationandefficiencywillbechangedbymodifiedoutputcable . 1.netweight:330~380gapprox. 2.optionaloutputconnectorsavailablecontactsalesfordetails. ratingchart: modelno. voltagerange (vdc) (a) (w) (w) (ms) (mvp-p) (%) (%) outputcurrent maximum outputpower ripple&noise totalregulation typ.efficiency noload consumption hold-uptime protectionmode olp olp olp olp olp olp olp 12 12 12 12 12 12 12 0.5 0.5 0.5 0.5 0.5 0.5 0.5 84 85 85 85 86 86 86 5 5 5 3 3 3 3 100 100 100 100 100 100 100 63 63 63 63 63 63 63 5.25 12.0 15.0 18.0 4.20 24.0 3.50 30.0 2.62 36.0 48.0 2.10 1.75 1.31 hpu63b-105 hpu63b-106 hpu63b-107 hpu63b-108 hpu63b-109 hpu63b-110 hpu63b-111 temperature(c) -10 0 10 0 10 20 30 40 50 60 70 80 90 100 110 20 30 40 50 60 70 80 (fig.2)temperaturederatingcurve inputvoltage(vac) load(%) 80 50 60 70 80 90 100 110 100 120 140 160 180 200 220 240 260 280 (fig.1)inputvoltagederatingcurve derate curves 0315 63w medical power adapters for health care applications ahp6301 series www.astrodynetdi.com astrodyne usa: 1-800-823-8082 astrodyne pacific: 886-2-26983458


▲Up To Search▲   

 
Price & Availability of AHP6301-09

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X